SerVision Ltd.
Page 5
Connecting a PTZ Camera to MVG400, UVG400 or HVG400
To connect a single PTZ camera to an MVG, UVG or HVG unit:
The HVG-400,MVG-400, and UVG-400 all have a 9-pin female PTZ connector on
the back panel.
In all units the connector supports both RS232 and RS485.
To connect an RS232 PTZ controller:
The RS232 controller cable should end with a female 9-pin RS232 connector.
• If you are only connecting the RS232 PTZ controller to the unit, and
are not connecting any RS485 PTZ controllers, plug the 9-pin RS232
connector directly into the RS232/485 connector on the rear panel of
the unit.
• If you are connecting one or more RS485 PTZ controllers to the unit,
plug the 9-pin RS232 connector into the RS232/485 adapter supplied
with the unit.
To connect an RS485 PTZ controller:
Each RS485 controller cable should end with two wires.
1. Use a wire connector to connect the wires to the RS485 connection wires
of the adapter. Be sure to match the positive (+) wire of the controller cable
to the positive (+ red) wire of the adapter, and the negative (-) wire of the
controller cable to the negative (- grey) wire of the adapter (see figure 2).
Figure 2: RS232/485 adapter
To connect multiple RS485 controllers to the adapter, insert the positive
(+) wires of all of the controllers into one slot in the wire connector, and
the negative (-) wires of all of the controllers into the other slot of the wire
connector.